wuxi zhonghui's NISPT-2 Non-integral Thermoplastic Insulated Parallel Cord is a high-quality cable designed for a wide range of applications. It features excellent electrical and physical properties, making it suitable for use in various environments. This cable is known for its durability and reliability, providing consistent performance. It is constructed with thermoplastic insulation, which offers good resistance to chemicals, moisture, and abrasion. The parallel cord design ensures efficient power transmission and is easy to install. Additionally, it meets relevant safety standards, ensuring secure and dependable operation. NISPT-2 is particularly noted for its superior load conditions compared to NISPT-1, making it ideal for more demanding applications
Performance Parameter
规格 C×AWG | 绝缘 Insulation | 护套 Jacket |
最大导体电阻 Max Resistance (Ω/km, 20℃) |
厚度 Nom.Thick. (mm) | 外径 Nom.Dia. (mm) | 厚度 Nom.Thick. (mm) | 外径 Nom.Dia. (mm) |
2× | 18 | 0.76 | 2.80 | 0.38 | 4.05×7.50 | 23.2 |
16 | 0.76 | 3.10 | 0.38 | 4.35×8.20 | 14.6 |
3× | 18 | 0.76 | 2.80 | 0.38 | 4.05×11.10 | 23.2 |
16 | 0.76 | 3.10 | 0.38 | 4.35×12.00 | 14.6 |
产品认证 Certification | 
| 
|
Product Specifications | Details |
Product Name | NISPT-2 Non-integral Thermoplastic Insulated Parallel Cord |
Rating Temp | 60℃, 75℃, 90℃, 105℃ |
Rating Volt. | 300V |
Reference Standard | UL62, UL2556 |
Conductor | Stranded bare or tinned copper conductor |
Insulation | PVC, ROHS compliant |
Jacket | PVC, ROHS compliant |
Application | Internal & exterior wiring for electronic appliances, power instruments, and auto equipments |
NISPT-2 Non-Integral Thermoplastic Insulated Parallel Cord
Product Features
-
Temperature and Voltage Rating: Available with temperature ratings of 60℃, 75℃, 90℃, and 105℃, and a voltage rating of 300V, ensuring reliable performance in various environments.
-
Standards Compliance: Adheres to UL62 and UL2556 standards, guaranteeing quality and safety for industrial and commercial applications.
-
Conductor Type: Features stranded bare or tinned copper conductors for excellent conductivity and flexibility.
-
Insulation and Jacket: Utilizes PVC insulation and jacketing, which are ROHS compliant, ensuring environmental safety.
-
Application Versatility: Suitable for internal and external wiring in electronic appliances, power instruments, and automotive equipment.
Product Advantages
-
Enhanced Safety: Compliance with international standards ensures safe operation in various environments.
-
Durability: High-quality materials and construction ensure long-lasting performance, even in demanding conditions.
-
Versatility: Suitable for a wide range of applications, including residential, commercial, and industrial settings.
-
Ease of Use: Uniform insulation thickness allows for easy stripping and cutting, making installation quick and efficient.
-
Environmental Friendliness: ROHS compliance ensures the product is safe for the environment.
-
Wide Application Range: Ideal for electronic appliances, power instruments, and automotive equipment, providing stable and reliable performance in critical systems.
FAQ (Frequently Asked Questions)
1. Q: What is the NISPT-2 Non-integral Thermoplastic Insulated Parallel Cord used for?
A:
The NISPT-2 Non-integral Thermoplastic Insulated Parallel Cord is designed for internal and external wiring in electronic appliances, power instruments, and automotive equipment. It is suitable for applications requiring reliable and safe power connections.
2. Q: What are the key features of the NISPT-2 Non-integral Thermoplastic Insulated Parallel Cord?
A:
The NISPT-2 Non-integral Thermoplastic Insulated Parallel Cord features a temperature rating of 60℃, 75℃, 90℃, and 105℃, with a voltage rating of 300V. It uses stranded bare or tinned copper conductors, PVC insulation, and jacketing that is ROHS compliant. It meets standards such as UL62 and UL2556.
3. Q: What applications is the NISPT-2 Non-integral Thermoplastic Insulated Parallel Cord suitable for?
A:
The NISPT-2 Non-integral Thermoplastic Insulated Parallel Cord is suitable for a wide range of applications, including internal and external wiring in electronic appliances, power instruments, and automotive equipment. It provides reliable performance in various electrical systems.
4. Q: How should I install and use the NISPT-2 Non-integral Thermoplastic Insulated Parallel Cord?
A:
Ensure the cable is installed in accordance with local electrical codes and standards. Avoid excessive bending or stretching. Use appropriate connectors and terminations to ensure a secure connection. Regularly inspect the cable for any signs of damage or wear.
5. Q: How should I maintain the NISPT-2 Non-integral Thermoplastic Insulated Parallel Cord?
A:
Regularly inspect the cable for physical damage or wear. Keep the cable clean and free from dirt and debris. Ensure connections are secure and free from corrosion. Replace the cable immediately if any damage is detected.
6. Q: Is the NISPT-2 Non-integral Thermoplastic Insulated Parallel Cord environmentally friendly?
A:
Yes, the NISPT-2 Non-integral Thermoplastic Insulated Parallel Cord is environmentally friendly. It meets ROHS standards and uses materials that are safe for the environment.
7. Q: What standards does the NISPT-2 Non-integral Thermoplastic Insulated Parallel Cord comply with?
A:
The NISPT-2 Non-integral Thermoplastic Insulated Parallel Cord complies with standards such as UL62 and UL2556, ensuring quality and safety for various electrical systems.